Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 60(6): 1468-72, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282700

RESUMO

BACKGROUND: Iodinated contrast during endovascular aneurysm repair (EVAR) is used with caution in patients with chronic kidney disease. Contrast-enhanced ultrasound (CEUS) imaging using nonnephrotoxic sulphur hexafluoride microbubble contrast is a novel imaging modality that accurately identifies and characterizes endoleaks during EVAR follow-up. We report our initial experience of using three-dimensional (3D) CEUS imaging intraoperatively as completion imaging after endograft deployment. Our aim was to compare intraoperative 3D CEUS against uniplanar angiography in the detection of endoleak, stent deformity, and renal artery perfusion during EVAR. METHODS: The study enrolled 20 patients undergoing elective conventional infrarenal EVAR, after which a completion angiogram was performed and the presence of endoleak, renal artery perfusion, or device deformity were recorded. With the patient still under anesthetic, a vascular scientist blinded to angiographic findings performed 3D CEUS and reported on the same parameters. RESULTS: Three endoleaks, one type I and two type II, were detected on uniplanar angiography and 13 endoleaks, 11 type II and two type I, were found using 3D CEUS imaging. Of note, one of these type I endoleaks was not seen on angiography, and this patient underwent balloon moulding of the neck with resolution of the endoleak on repeat imaging. Of the 11 type II endoleaks seen with 3D CEUS imaging, the inflow vessel was identified in nine cases. No graft deformity or limb kinking was seen in any patient. Both renal arteries could be visualized in 10 patients, whereas the target renal artery was seen in 11 patients. In the remaining patients, the renal arteries could not be visualized, mainly due to intra-abdominal gas or patient body habitus. CONCLUSIONS: 3D CEUS imaging detected endoleaks not seen on uniplanar digital subtraction angiography, including a clinically important type I endoleak, and was also more sensitive than 2D CEUS imaging for the detection of the source of endoleak. This technology has the potential to supplement or replace digital subtraction angiography for completion imaging to reduce the use of x-ray contrast. Intraoperative 3D CEUS has been applied to allow safe EVAR with ultralow or no iodinated contrast usage in selected cases, without compromising completion imaging.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/efeitos adversos , Meios de Contraste , Procedimentos Endovasculares/efeitos adversos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Complicações Pós-Operatórias/diagnóstico por imagem , Hexafluoreto de Enxofre , Ultrassonografia Doppler Dupla , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Aneurisma Aórtico/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Microbolhas , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Falha de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...